ANALISIS KINERJA PENURUNAN TINGKAT PENCEMARAN AIR PERMUKAAN PADA LINGKUNGAN SEKITAR INSTALASI PENGOLAHAN LUMPUR TINJA (IPLT) KOTA KENDARI


Ningrum, Ulfah Dwi (2020) ANALISIS KINERJA PENURUNAN TINGKAT PENCEMARAN AIR PERMUKAAN PADA LINGKUNGAN SEKITAR INSTALASI PENGOLAHAN LUMPUR TINJA (IPLT) KOTA KENDARI. Thesis thesis, Universitas Hasanuddin.

[thumbnail of sampul]
Preview
Image (sampul)
P0302216003_tesis(FILEminimizer) cover.png

Download (150kB) | Preview
[thumbnail of dapus] Text (dapus)
P0302216003_tesis(FILEminimizer) dapus.pdf

Download (22kB)
[thumbnail of bab 1-2] Text (bab 1-2)
P0302216003_tesis(FILEminimizer) 1-2.pdf

Download (1MB)
[thumbnail of full teks] Text (full teks)
P0302216003_tesis(FILEminimizer)---------------.pdf
Restricted to Repository staff only

Download (1MB)

Abstract (Abstrak)

ULFAH DWI NINGRUM. Analisis Kinerja Penurunan Tingkat Pencemaran Air Permukaan Pada Lingkungan Sekitar Instalasi Pengolahan Lumpur Tinja (IPLT) Kota Kendari. (dibimbing oleh Sri Suryani dan Eymal Bahsar Demmallino)

Penelitian ini dilakukan dengan melihat perkembangan IPLT Kota Kendari yang tidak berjalan baik, sehingga dalam pelaksanaanya dilakukan optimalisasi pada tahun 2018 oleh Kementerian PUPR dibawah kendali Satuan Kerja PSPLP. Setelah dilakukan optimalisasi, maka dipandang perlu di adakan penelitian pada IPLT Puulonggida Kota Kendari. IPLT ini di desain untuk mengolah lumpur tinja sebanyak 80m³/hari dengan sistem on call. Tujuan penelitian ini adalah untuk mengetahui kandungan pencemar pada efluen yang dihasilkan dari proses pengolahan IPLT Kota Kendari dan untuk mengetahui perbandingan tingkat pencemar setelah melalui proses pengolahan pada IPLT Kota Kendari.
Metode yang digunakan adalah deskriptif kuantitatif, yaitu menggambarkan kondisi IPLT Kota Kendari dan mendeskripsikan hasil penelitian menggunakan data kuantitatif yang terukur.
Hasil analisis kandungan pencemar pada efluen yang dihasilkan dari proses pengolahan IPLT Kota Kendari yaitu memiliki nilai BOD5 (5,80 mg/L, COD (12,60 mg/L) dan TSS (81,95 mg/L), pH(7,66-7,85), minyak dan lemak (0,235 mg/L), amoniak (0,418 mg/L) dan total Coliform (<3,0x103) yang memenuhi baku mutu air limbah menurut PERMEN LHK No. 68 Tahun 2016 dan SNI tahun 2004. Kualitas air tanah juga di bawah stnadar baku mutu yaitu tidak berwarna, tidak berbau, nilai Coliform sebesar 12 CFU/100 ml, TSS 191mg/L, minyak lemak 0,22mg/L dan amoniak 0,005 mg/L. Sedangkan Perbandingan tingkat pencemar sebelum dan setelah melalui proses pengolahan pada IPLT Kota Kendari yaitu outlet memiliki nilai yang lebih rendah dari inlet baik pada BOD5, COD, pH, minyak dan lemak, amoniak, Mbas (deterjen) dan Coliform yang memenuhi baku mutu air limbah menurut PERMEN LHK No. 68 Tahun 2016 dan SNI tahun 2004. Adapun hasil analisis indeks pencemaran menunjukkan bahwa kualitas efluen IPLT memiliki nilai 0,466 dimana kualitas air limbah masuk kategori memenuhi baku mutu PERMEN LHK No. 68 Tahun 2016 tentang Baku Mutu Air Limbah Domestik dan hal ini menunjukkan bahwa kegiatan IPLT tidak memberikan dampak negative terhadap kualitas air tanah dan lingkungan sekitar IPLT.

Ulfah Dwi Ningrum. Performance Analysis of Reduction of Surface Water Pollution Levels in the Around of Septage Treatment Plant (IPLT) in Kendari City. (supervised by Sri Suryani and Eymal Bahsar Demmalino)

This research was conducted by looking at the development of IPLT’s Kendari City which was not going well, so that in its implementation, optimization was carried out in 2018 by the Ministry of PUPR under control of PSPLP Work Unit. After the optimization is done, it is deemed necessary to condust research on IPLT Puulongida Kendari City. The IPLT is designed to treat as much as 80m³.day with an on call system. The purpose of this study was to determined the pollutant content of the effluent produced from the Kendari City IPLT processing and to determine the comparison of pollutant levels after going through the processing process at the Kendari City IPLT.
The method used is quantitative descriptive, which describes the conditions of the IPLT in Kendari City and describes the results of the research using quatitative measured data.
The results of the analysis of pollutant content in the effluent produced from the IPLT processing were BOD (5.80mg/L), COD (12.60 mg/L), and TSS (81.95 mg/L), pH (7.66-7.85), oils and fats (0.235 mg/L), ammonia (0.418 mg/L) and Total Coliform (<3.0x103) which meet the quality standards of waste water according to the PERMEN LHK No. 68/2016 and SNI year 2004. Whereas the comparison of pollutant levels before and after going through the processing process at the Kendari City IPLT, namely the outlet has a lower value than the inlet both for BOD, COD, pH, oils and fats, ammonia, Mbas (detergent) and Coliform which meet the water quality standards was according to PERMEN LHK No. 68/2016 and SNI 2004. The results of the analysis pollution index show that the quality of the IPLT effluent has a value of 0,466 where the quality of wastewater is categorized as meeting the quality standards of the PERMEN LHK No.68/2016 and this show that IPLT activities do not have a negative impact on groundwater quality and the environment around the IPLT.

Item Type: Thesis (Thesis)
Uncontrolled Keywords: IPLT, kandungan efluen, inlet dan outlet IPLT, effluent, inlet, and outlet
Subjects: T Technology > TD Environmental technology. Sanitary engineering