Optimized Micro-Pattern Design and Fabrication of a Light Guide Plate Using Micro-Injection Molding


Muhammad Ruslin, - Optimized Micro-Pattern Design and Fabrication of a Light Guide Plate Using Micro-Injection Molding. Polymers 2021, 13, 4244.

[thumbnail of 12. 2021 Optimized micro-pattern design and fabrication of a light guide plate using micro-injection molding.pdf] Text
12. 2021 Optimized micro-pattern design and fabrication of a light guide plate using micro-injection molding.pdf
Restricted to Repository staff only

Download (7MB)

Abstract (Abstrak)

This study examined the uniformity of illuminance field distributions of light guide plates (LGPs). First, the authors designed microstructural patterns on the surface of an LGP. Then, a mold of the LGP with the optimal microstructural design was fabricated by a photolithography method. Micro-injection molding (μIM) was used to manufacture the molded LGPs. μIM technology can simultaneously manufacture large-sized wedge-shaped LGPs and micro-scale microstructures. Finally, illuminance values of the field distributions of the LGPs with various microstructures were obtained through optical field measurements. This study compared the illuminance field distributions of LGPs with various designs and structures, which included LGPs without and those with microstructure on the primary design and the optimal design. The average illuminance of the LGP with microstructures and the optimal design was roughly 196.1 cd/m2 . Its average illuminance was 1.3 times that of the LGP without microstructures. This study also discusses illuminance field distributions of LGPs with microstructures that were influenced by various μIM process parameters. The mold temperature was found to be the most important processing parameter affecting the illuminance field distribution of molded LGPs fabricated by μIM. The molded LGP with microstructures and the optimal design had better uniformity than that with microstructures and the primary design and that without microstructures. The uniformity of the LGP with microstructures and the optimal design was roughly 86.4%. Its uniformity was nearly 1.65 times that of the LGP without microstructures. The optimized design and fabrication of LGPs with microstructure exhibited good uniformity of illuminance field distributions.

Item Type: Article
Subjects: R Medicine > RK Dentistry
Depositing User: - Andi Anna
Date Deposited: 18 Nov 2022 07:09
Last Modified: 18 Nov 2022 07:09
URI: http://repository.unhas.ac.id:443/id/eprint/23370

Actions (login required)

View Item
View Item